PE Power exam practice questions
Every answer,
worked out in full.
Original practice questions for the PE Electrical and Computer: Power exam. Each one has a worked solution and a video solution, all written and checked by AI. Every answer is recomputed by a script before it is published.
Written and checked by AI
The questions, worked solutions and video solutions are written and checked by AI (Claude, by Anthropic).
No human engineer or licensed PE reviews each question before it is published.
Before a question goes live, a separate script, also AI-written, recomputes its answer from the given data.
A separate Claude session also solves it without seeing the solution or the key.
A match is strong evidence, not proof that every answer is right.
The exam has nine knowledge areas. PhasorPrep has no Electrical Safety questions yet, and that area is 10 to 15 of the exam's 80 questions, so you will need another source for it.
How it works
Find your weak areas
Take the free diagnostic: a short mixed set across the exam's knowledge areas, scored by area, so you know where your study hours should go.
Practice with worked solutions
Work original questions one at a time. Every solution shows each step with its units, and every numeric answer is checked by a script before it is published.
Rehearse the real thing
Sit a timed, computer-based practice exam with flag-and-review, then go through every answer with its full solution.
See a full worked solution
Every question comes with the method, every number and the mistakes that lead to each wrong choice. Try this one first.
A 20 MVA, 69 kV Δ / 13.8 kV grounded-wye transformer has a leakage impedance of 8% on its own rating. The 69 kV source may be treated as infinite. Neglecting resistance and pre-fault load current, the three-phase bolted fault current at the 13.8 kV terminals is most nearly:
- Choice A: 2.09 kA
- Choice B: 6.04 kA
- Choice C: 10.5 kA
- Choice D: 18.1 kA
Show solution
- Choice A: 2.09 kA
- Choice B: 6.04 kA
- Choice C: 10.5 kACorrect answer
- Choice D: 18.1 kA
Solution
-
Choose the transformer rating as the base: , on the secondary side. The transformer impedance is already on this base: .
-
An infinite source contributes no impedance, so the Thévenin impedance at the fault is .
-
Base current on the 13.8 kV side:
- For a three-phase bolted fault with 1.0 pu pre-fault voltage:
The answer is (C) 10.5 kA.
Common mistakes
- Leaving out in the base current () → 18.1 kA (D).
- Using the 69 kV side for the base current (167.3 A) → 2.09 kA (A), which is the fault current seen on the primary, not at the 13.8 kV terminals.
- Dividing by a second time to get a "phase" current → 6.04 kA (B).
Watch it worked out
The one-line diagram, each step built up on screen, and the mistake behind choice D.
Free calculators, live now
Eleven calculators for the power-system arithmetic the exam leans on. Each shows its formulas, a worked example and its assumptions.
Per-unit converter
Base current and impedance, and an impedance moved from one MVA and kV base to another.
Open the calculatorFault current calculator
Three-phase and line-to-ground fault current at a delta–wye-grounded transformer's secondary.
Open the calculatorVoltage drop calculator
Feeder voltage drop from current, length, conductor R and X, and power factor.
Open the calculatorThree-phase power calculator
kW, kVA, kVAR, line current and power factor from the line voltage and any two of them.
Open the calculatorPower-factor correction calculator
Capacitor kVAR and µF per phase to raise a lagging power factor, and the line current before and after.
Open the calculatorSymmetrical components calculator
Phase phasors to zero, positive and negative sequence components and back, drawn as phasors.
Open the calculatorTransformer current calculator
Primary and secondary full-load current, and the largest secondary fault current its impedance allows.
Open the calculatorMotor-starting voltage dip calculator
Bus voltage while a motor starts across the line, from the source, the transformer and the motor's locked-rotor kVA.
Open the calculatorTwo-wattmeter method calculator
Total power, reactive power and power factor of a balanced three-wire load from its two wattmeter readings.
Open the calculatorInduction motor slip calculator
Synchronous speed, slip and rotor frequency of an induction motor from the supply frequency, its poles and its shaft speed.
Open the calculatorLocked-rotor amps calculator
Locked-rotor kVA and current of an induction motor from its horsepower, rated voltage and locked-rotor kVA per horsepower.
Open the calculator
Reading before practising? Study guides for each exam area, each linked to the calculators that fit it.
What's inside
Free diagnostic
A short mixed set that scores you by knowledge area. Free with a Google sign-in.
FreePractice by area
Original questions in the exam's knowledge areas, each with a step-by-step worked solution and a video solution.
Free samplesExam simulator
A half-length exam, 40 questions in 4 hours, or the full 80-question exam in 8 hours. Simulated exams have no Electrical Safety questions yet; they draw on the other eight areas.
PE Power Pass
Start with the free diagnostic
A short timed set across the exam areas, scored by area, with every worked solution at the end. Free with a Google sign-in.
One pass, one price
One payment of $49 for 6 months of full access, with no subscription. Every question published during your pass is included, and there is a full refund within 14 days.
Get the 6-month pass — $49Questions
Something not covered here? Write to support@phasorprep.com.